logo
products

ZM-A Single Section Wall Cabinet - 60kg Loading Capacity Welded Steel Structure with 180° Glass Front Door

Grundlegende Informationen
Herkunftsort: China
Markenname: Zion communication OR OEM
Zertifizierung: ISO, CE, RoHS, UL
Modellnummer: Netzwerk-Rack-Schrank
Min Bestellmenge: 1.000 PC
Verpackung Informationen: 1 PC-/Plastictasche, PCS/Carton
Lieferzeit: Normalerweise 10 Arbeitstage
Zahlungsbedingungen: T/T, L/C
Versorgungsmaterial-Fähigkeit: 30.000 PCS/Monat
Detailinformationen
Modell: Netzwerk-Rack-Schrank Bnad: Zion-Kommunikation
Farbe: Schwarz, Grau Ladekapazität: 60kg
Hervorheben:

60kg Loading Capacity Wall Cabinet

,

Welded Steel Structure Network Rack Cabinet

,

180° Glass Front Door 19-inch Enclosure


Produkt-Beschreibung

ZM-A Single Section Wall Cabinet

The ZM-A Single Section Wall Cabinet is a compact 19-inch wall-mounted enclosure designed for small network nodes, CCTV systems, telecom distribution points, access switches, and other light-duty edge equipment where secure installation, clean routing, and service access matter.

Network Integrators
CCTV Installers
Telecom Contractors
IT Procurement Teams
Project Managers
Edge Deployment Teams
Quick Takeaway
  • A practical 19-inch wall cabinet for small and medium edge deployments.
  • Best used where floor-standing cabinets are unnecessary and wall space is available.
  • Before ordering, confirm U height, device depth, wall condition, ventilation need, and accessory plan.
Reserved Image Module

Add product main photo, open-door view, internal mounting profile photo, or installation scene image here.

Reserved Video Module

Suitable for factory video, installation demo, door opening demo, or accessory explanation video.

1) Overview

The ZM-A Single Section Wall Cabinet is positioned as a compact welded-steel 19-inch enclosure for edge-side communication and security infrastructure. It is intended for small network nodes, CCTV installations, telecom distribution points, access switches, and other equipment that does not justify a floor-standing cabinet.

From an engineering and procurement perspective, the value of this product is not just cabinet size. It comes from the combination of welded structure, wall-mounted installation, removable side panels, front-door access, flexible cable entry, adjustable mounting profiles, and optional accessory support. That makes it suitable for projects where space efficiency, clean serviceability, and installation control are more important than oversized rack capacity.

Field reality

Wall cabinets solve floor-space problems, but the real project decision still depends on wall strength, service clearance, heat buildup, cable direction, and whether the chosen depth actually matches the installed equipment.

ZM-A Single Section Wall Cabinet - 60kg Loading Capacity Welded Steel Structure with 180° Glass Front Door 0

2) Key Features

The ZM-A cabinet is designed to simplify real installation and maintenance work rather than only look correct on paper. Its structure and access logic support typical edge deployments where devices need protection, cable organization, and reasonable future service access.

Feature What It Means Project Benefit
Welded Steel Cabinet Rigid single-section structure Improves stability and reduces assembly complexity on site
19″ Equipment Ready Supports standard IT, telecom, and security devices Simplifies equipment compatibility planning
180° Glass Front Door Wide opening front access Makes installation, patching, and inspection easier
Removable Side Panels Quick side access with optional lock Reduces maintenance difficulty in tight installations
Top & Bottom Cable Entry Knock-out design for flexible cable routing Adapts to different conduit and routing directions
Adjustable Mounting Rails L-shaped mounting profiles for depth adjustment Supports more accurate equipment fitment
Fan-Ready Top Panel Supports active ventilation Useful when switch, NVR, or power load raises internal temperature
Accessory Compatible Can work with shelves, PDUs, and cable managers Improves project flexibility and standardization

3) Technical Specifications

Item Specification
Rack Standard 19-inch
Frame Material SPCC high-quality cold rolled steel
Mounting Profile Thickness 1.2 mm
Other Parts Thickness 1.0 mm
Surface Treatment Degreasing → Pickling → Phosphating → Electrostatic Powder Coating
Static Loading Capacity Up to 60 kg
Protection Level IP20
Front Door Tempered glass front door
Door Opening 180°
Cable Entry Top and bottom cable entry
Ventilation Fan-ready top panel
Standards Compliance ANSI/EIA RS-310-D, IEC 60297-2, DIN 41497 Part 1, DIN 41494 Part 7, GB/T 3047.2-92
Color Options RAL 9004, RAL 7035, other color optional
Key takeaway
IP20 means indoor use is the baseline.
60 kg static load fits light-duty rack equipment, not heavy central-room builds.
Depth and wall condition should be confirmed before final model approval.

ZM-A Single Section Wall Cabinet - 60kg Loading Capacity Welded Steel Structure with 180° Glass Front Door 1

4) Construction / Materials

The ZM-A cabinet uses SPCC cold rolled steel as the main structural material, paired with tempered glass for the front door. The result is a cabinet that balances rigidity, visibility, and practical front-side serviceability.

Component Qty Material / Spec Surface Finish Notes
Top Cover 1 pc SPCC cold rolled steel, T1.2 Powder coated
Bottom Panel 1 pc SPCC cold rolled steel, T1.2 Powder coated
Frame 2 pc SPCC cold rolled steel, T1.2 Powder coated
Mounting Profile 4 pcs SPCC cold rolled steel, T1.5 Powder coated Depth adjustable
Side Panel 2 pcs SPCC cold rolled steel, T1.2 Powder coated Removable
Front Door 1 pc Tempered glass 5 mm Powder coated Multiple door options possible
Lock 1 pc Galvanization Powder coated
Cable Entry Plate 2 pcs SPCC cold rolled steel, T1.2 Powder coated Top/bottom cable entry
Installing Back Panel 1 pc SPCC cold rolled steel, T1.2 Powder coated Wall mount structure

5) Applications

This cabinet is best used in projects where equipment concentration is limited, access control is still required, and space efficiency matters. It is not intended to replace larger floor-standing cabinets in high-density core environments.

Application Scenario Why ZM-A Fits What to Verify Before Approval
Small network node Compact 19-inch enclosure with wall-mounted footprint Depth, cable direction, future expansion
CCTV system point Supports switch, recorder, patching, and accessories in one enclosure Heat load, lock option, service frequency
Telecom distribution point Organized indoor enclosure for access-side telecom equipment Wall mounting condition, cable entry planning
Branch office access switch location Suitable where a full rack is oversized for the site Equipment depth, shelf needs, local power arrangement
Indoor light-duty communication point Provides controlled enclosure without consuming floor area Environmental limits, maintenance access, accessory compatibility

ZM-A Single Section Wall Cabinet - 60kg Loading Capacity Welded Steel Structure with 180° Glass Front Door 2

6) Decision Rules / Engineer’s Shortcut

For engineering teams, the fastest correct decision is to evaluate installation type, load level, depth requirement, environment, and service pattern first. That avoids the common mistake of choosing a wall cabinet by U height alone.

Decision Point Choose ZM-A When Do Not Choose It When Alternative Direction Cost / Risk / Maintainability Impact
Installation type A wall-mounted 19-inch enclosure is required The project needs floor-standing scale or central-room expansion Use a floor-standing cabinet Correctly chosen wall cabinets save space and cost
Load level The equipment load stays within 60 kg static capacity The deployment includes heavier equipment or larger structural reserve is needed Select a higher-load cabinet platform Wrong load planning increases safety risk
Environmental protection The site is indoor and IP20 is acceptable Outdoor or higher ingress protection is required Use higher-protection indoor/outdoor enclosure Using IP20 in the wrong environment increases maintenance and failure risk
Depth suitability 450 mm, 600 mm, or 800 mm options match real device depth Equipment body plus cable allowance exceeds usable space Move to deeper cabinet or different structure Depth mismatch is a common procurement mistake
Thermal behavior Heat load is moderate and fan-ready top panel is enough The site has dense hot equipment without ventilation planning Choose a cabinet with stronger thermal management space Ignoring heat reduces equipment life and increases downtime risk
Maintenance access Front access and removable side panels fit the service plan The site requires unusually frequent rear access or larger internal work area Use a cabinet format with more service clearance Right access logic lowers field labor and rework
Practical rule

If the project is indoor, wall-mounted, light-duty, and depth-appropriate, ZM-A is usually a strong fit. If any of those four conditions fail, reevaluate before purchase.

7) Selection Guide

A correct model choice should be based on actual equipment size, reserve capacity, routing method, accessory plan, and project delivery logic. This is especially important in B2B purchasing, where late changes in depth or accessories can disrupt both lead time and installation.

Selection Factor Question to Ask Recommendation
U height How many rack units are needed now and after expansion? Add reserve space instead of ordering to the exact current load
Depth What is the deepest device, including connector and cable bend allowance? Do not choose by cabinet label alone; check usable space
Door style Is visibility, airflow, or a different front-door configuration needed? Review glass, vented, or meshed options early
Accessory plan Will shelves, PDU, cable manager, or lock options be included? Bundle accessories in the original RFQ
Color Does the project require standard or custom appearance? Standard colors usually reduce delivery complexity
Delivery risk Are there custom doors, colors, or optional parts? Freeze the exact BOM before production scheduling

8) Model List

Model No. Height (U) Width (mm) Depth (mm)
ZMA-6404 4U 600 450
ZMA-6406 6U 600 450
ZMA-6409 9U 600 450
ZMA-6412 12U 600 450
ZMA-6415 15U 600 450
ZMA-6418 18U 600 450
ZMA-6422 22U 600 450
ZMA-6427 27U 600 450
ZMA-6815 15U 600 800
Model No. Height (U) Width (mm) Depth (mm)
ZMA-6404 4U 600 600
ZMA-6406 6U 600 600
ZMA-6409 9U 600 600
ZMA-6412 12U 600 600
ZMA-6415 15U 600 600
ZMA-6418 18U 600 600
ZMA-6422 22U 600 600
ZMA-6427 27U 600 600
ZMA-6818 18U 600 800

9) FAQ

1. What equipment is this cabinet mainly designed for?

It is intended for small network nodes, CCTV systems, telecom distribution points, access switches, and other light-duty 19-inch edge equipment.

2. Is this cabinet suitable for outdoor installation?

No. The stated protection level is IP20, so the baseline application is indoor use.

3. How should I choose between 450 mm, 600 mm, and 800 mm depth?

Check the deepest device first, then add allowance for front connectors, cable bend radius, and maintenance clearance. If there is any doubt, do not select by nominal cabinet size alone.

4. What optional accessories or variations are available?

Optional items may include removable side panel with optional lock, cantilever shelf, fixed shelf, multiple front door options, cable entry brush, and smoked color glass.

5. Does it support ventilation upgrades?

Yes. The top panel is fan-ready, which is useful when active ventilation is needed for enclosed equipment.

6. What should procurement confirm before placing an order?

Confirm model number, U height, depth, wall-mount condition, door option, color, accessory list, and whether the site load and service plan fit the cabinet’s intended application.

10) Conclusion

The ZM-A Single Section Wall Cabinet is a practical wall-mounted solution for compact 19-inch network, CCTV, and telecom deployments. Its value comes from a balanced combination of structural rigidity, access convenience, cable-entry flexibility, and model variety rather than from marketing language alone.

For best project results, evaluate the cabinet by real use conditions: wall installation, equipment depth, indoor environment, thermal behavior, and accessory requirements. When those conditions align, the ZM-A becomes a reliable and cost-effective enclosure choice for edge-side infrastructure.

Kontaktdaten
Zion Communication

Telefonnummer : +8618268009191

WhatsApp : +8615088607575